← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard Plus Phenolic Epoxy High-temperature Tank Coating

Quick Specs

Tankguard Plus Phenolic Epoxy High-Temperature Storage Tank Coating belongs to Epoxy. Industrial protective coatings field: dedicated as lining coating for offshore, onshore, underground storage tanks and pipelines such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water supply lines and drilling mud tanks. The product has excellent chemical resistance and can withstand crude oil up to 160 °C. Parameters on this page: volume solids 70 ± 2%, dry film thickness 100–150 µm, theoretical spreading rate 7–4.7 m²/L.

Parameter source: JOTUN original technical data sheet (TDS) "Tankguard Plus Phenolic Epoxy High-Temperature Storage Tank Coating"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids70 ± 2%
Dry Film Thickness100–150 µm
Theoretical Spreading Rate7–4.7 m²/L
VOC270 g/L (China)
Density / Specific Gravity1.6 kg/L
Number of ComponentsTwo-component
Flash Point28 °C
ThinnerJotun Thinner No. 17 / JOTUN Thinner No. 23
Mixing Ratio4 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does Tankguard Plus have?
Tankguard Plus is a two-component product. Mix according to the mixing ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of Tankguard Plus?
The mixing ratio of Tankguard Plus is 4 parts : 1 part (by volume).
What is the typical dry film thickness of Tankguard Plus?
The typical dry film thickness of Tankguard Plus is 100–150 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Tankguard Plus?
The theoretical spreading rate of Tankguard Plus is 7–4.7 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Tankguard Plus?
The volume solids of Tankguard Plus is 70 ± 2%.
What is the VOC of Tankguard Plus?
The VOC of Tankguard Plus is 270 g/L (China).
What thinner is used for Tankguard Plus?
Recommended thinner for Tankguard Plus: Jotun Thinner No. 17 / Jotun Thinner No. 23.
What is the flash point of Tankguard Plus?
The flash point of Tankguard Plus is 28 °C. Storage, transport and application shall follow the product safety data sheet.
How long does Tankguard Plus take to dry?
Drying time of Tankguard Plus under standard conditions: touch dry 24 h; actual drying is affected by temperature, film thickness and ventilation.
Which standards are involved for Tankguard Plus?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard Plus be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard Plus

Product description

This is a two-component polyamine-cured phenolic epoxy coating. It is highly resistant to most sour crude oils, many chemicals and solvents. The product has excellent chemical resistance and can withstand crude oil up to 160 °C. It can be used as primer, intermediate coat or topcoat in atmospheric and immersion environments. Suitable for properly prepared carbon steel, galvanized steel, stainless steel and concrete substrates.

Typical Use

Industrial protective coatings:

Dedicated as lining coating for offshore, onshore, underground storage tanks and pipelines such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water supply lines and drilling mud tanks. This coating has good resistance to high-temperature products. Refer to the industrial protective coatings resistance table.

Others

Colour

Light yellow, white

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323370± 2 %
Gloss (GU 60°)ISO 2813Semi-gloss (35–70)
Flash PointISO 3679 Method 128 °C
DensityTheoretical Value1.6 kg/L
RegionRegulationsTest / StandardVOC Value
ChinaMandatory national standard of ChinaGB 30981.2-2025270 g/L
Coating hazards GB30981.2-S-Pb≤1000-NC

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness100–150 µm
Wet Film Thickness140–215 µm
Theoretical Spreading Rate7–4.7 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.
ConcreteDry abrasive blast clean to SSPC-SP 13 / NACE No. 6.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.
Roller:Roller application may be used only in areas such as drain holes, rat holes and small pipes.

Mixing Ratio (by Volume)

Tankguard Plus Comp A — Phenolic Epoxy High-Temperature Tank Coating, Component A4 parts
Phenolic Epoxy High-Temperature Tank Coating, Component B1 part

Thinner / Cleaning Solvent

ThinnerJotun Thinner No. 17 / JOTUN Thinner No. 23

Airless Spray Guidance

Nozzle tip size (inch/1000):17-21
Nozzle pressure (minimum):150 bar/2100 psi

Drying and Curing Time

Substrate Temperature5 °C10 °C15 °C23 °C30 °C40 °C
Touch Dry24 h16 h6 h4 h3 h2 h
Walk-on Dry36 h24 h10 h7 h5 h3 h
Minimum recoat interval52 h36 h30 h20 h14 h10 h
Dry/cured to service14 days10 days7 days5 days4 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

If high-temperature curing is applied, Tankguard Plus can be returned to service after half of the "drying/curing to service" time, as follows:

5 °C: 7 days including 8 h at 60 °C 10 °C: 5 days including 8 h at 60 °C 15 °C: 3.5 days including 8 h at 60 °C 23 °C: 2.5 days including 8 h at 60 °C 30 °C: 2 days including 8 h at 60 °C 40 °C: 1.5 days including 8 h at 60 °C High-temperature curing (air) can be initiated after the final coat reaches "dry to overcoat" and can be achieved by heating the steel with high-temperature air and maintaining the temperature at 60 °C for 8 h. Total curing time shall be as above.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Induction Time15 min
Pot Life2 h

Heat Resistance

Temperature

Drying, atmosphericContinuous 160 °CPeak -
Immersed, sea water90 °C95 °C
Immersed, crude oil160 °C-

For more detailed resistance information, see the Industrial Protective Products Resistance List on the JOTUN website, or contact your local JOTUN office.

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:itself
Subsequent coat:itself

Typical Packaging Sizes

VolumeContainer Size
(L)
Tankguard Plus Comp A — Phenolic Epoxy High-Temperature Tank Coating, Component A1620
Phenolic Epoxy High-Temperature Tank Coating, Component B45

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Tankguard Plus Comp A — Phenolic Epoxy High-Temperature Tank Coating, Component A24 months
Phenolic Epoxy High-Temperature Tank Coating, Component B24 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery