← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

SteelMaster 60WB Interior Intumescent Steel Fire Protection

Quick Specs

SteelMaster 60WB Interior Intumescent Structural Steel Fire Protection Coating is a fire protection coating. Suitable for steel structures exposed to C3 and below internal environments as defined by ISO 12944-2. Independently certified for the fire protection of structural steel exposed to cellulosic fires. Parameters on this page: volume solids 72 ± 3%, dry film thickness 200-720 µm, number of components: one-component. Comparable models from the same brand: Jotachar 1709 XT epoxy intumescent coating, Jotachar 1709 exterior intumescent structural steel fire protection coating, Jotachar JF750 XT epoxy intumescent coating.

Parameter source: JOTUN original technical data sheet (TDS) for SteelMaster 60WB Interior Intumescent Structural Steel Fire Protection Coating; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids72 ± 3%
Dry Film Thickness200–720 µm
Theoretical Spreading Rate—
VOCGB/T 23986-2009 10.4 0 g/L (China)
Density / Specific Gravity1.4 kg/L
Number of ComponentsOne-component
Flash Point63 °C
Wet Film Thickness300–1000 µm

Browse Similar Models by CategoryThis model belongs to: Fire Protection

FAQ

How many components is SteelMaster 60WB?
SteelMaster 60WB is a one-component product. After opening, stir thoroughly and it is ready for application; no on-site mixing is required.
What dry film thickness is typically applied for SteelMaster 60WB?
The typical dry film thickness of SteelMaster 60WB is 200-720 µm; the specific value is determined by the coating system and design requirements.
What is the volume solids of SteelMaster 60WB?
The volume solids of SteelMaster 60WB is 72 ± 3%.
What is the VOC of SteelMaster 60WB?
The VOC of SteelMaster 60WB is GB/T 23986-2009 10.4 0 g/L (China).
What is the flash point of SteelMaster 60WB?
The flash point of SteelMaster 60WB is 63 °C. Storage, transport and application are subject to the product safety data sheet.
How long does SteelMaster 60WB take to dry?
Drying time of SteelMaster 60WB under standard conditions: touch dry 8 h; the actual value is affected by temperature, film thickness and ventilation.
Which standards apply to SteelMaster 60WB?
As recorded in the technical data on this page: suitable for application to steel structures in interior environments of C3 and below as defined in ISO 12944-2; GB/T 23986-2009 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can SteelMaster 60WB be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

SteelMaster 60WB

Product description

This is a single-component, thin-film intumescent water-borne acrylic coating. Independently certified for fire protection of structural steel exposed to cellulosic fires. In atmospheric environments, it may be used as an intermediate coat or topcoat. Suitable for carbon steel substrates coated with an approved primer.

Typical Use

A passive fire protection coating specifically for steel structures. Suitable for steel structures exposed to C3 and below internal environments as defined by ISO 12944-2.

Others

Approvals and Certificates

ASTM E84

Colour

White, grey

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323372± 3 %
Flash PointISO 3679 Method 163 °C
DensityTheoretical Value1.4 kg/L
RegionRegulationsTest / StandardVOC Value
ChinaGB 30981-2020 Limit of harmful substances of industrial protective coatingsGB/T 23986-2009 10.4 0 g/L
Coating hazards GB30981.2-W-Pb≤1000-NC

The data listed are based on factory batch production and may vary slightly with colour.

Solids content measured in accordance with ISO 3233 and the ASFP-BCF guidance method. The VOC content is based on the white paint.

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness200–720 µm
Wet Film Thickness300–1000 µm

All steelwork must be coated at the correct film thickness to achieve the required fire rating. Refer to the current thickness tables. For details, consult your local JOTUN office.

NoteThe single-coat film thickness applies to airless spray only.

Surface Preparation

For further information, see the Application Guide.

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Coated surfaceA clean, dry and sound compatible primer.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for stripe coating and small areas.

Product mixing

One-component

Thinner / Cleaning Solvent

Do not add thinner. Not to be thinned; ready for use.

CleanerFresh water

Airless Spray Guidance

Nozzle tip size (inch/1000):17-23
Nozzle pressure (minimum):200 bar/2900 psi

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry8 h4 h2 h1 h
Handle dry24 h16 h6 h4 h
Minimum recoat interval24 h16 h6 h4 h

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

All drying times are measured at 1000 µm wet film, under controlled temperature and relative humidity below 80%.

Topcoat:

The minimum recoating interval of the product is 48 h. The coating should reach handling dry, and the film thickness gauge should not leave indentations in the coating. When the temperature drops sharply or multiple coats are applied, the drying time and recoating interval may be extended. Before applying the topcoat, the applicator must ensure that the rated dry film thickness has been reached.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Handle dryThe minimum time after application before handling will not damage the film.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Alkyd, epoxy, epoxy zinc phosphate, zinc epoxy (with epoxy tie coat)
Subsequent coat:Approved topcoat list

The matched primer and topcoat must be compatible with the fire protection coating to ensure its fire protection performance.

SteelMaster 60WB — Interior Intumescent Fire Protection for Structural Steel (0SM)

Contact your local JOTUN office for the approved primer and topcoat list.

Typical Packaging Sizes

VolumeContainer Size
(L)
SteelMaster 60WB — Interior Intumescent Fire Protection for Structural Steel (0SM)18.520

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

During storage and transport, the temperature must be between 5 °C and 25 °C. In addition, climate control is recommended. Avoid frost during transport and storage.

Shelf Life at 23 °C

SteelMaster 60WB 6 months. Interior Intumescent Structural Steel Fire Protection Coating (0SM)

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Environmental documentation

This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.

EPDs are available at www.epd-norge.no

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — Fire protection

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery