China-based coatings exporter — industrial & marine protective coatings from China's production bases

Resist 86 Inorganic Zinc Silicate Primer

Quick Specs

Resist 86 Inorganic Zinc Silicate Primer belongs to zinc-rich primers. Industrial protective coatings field: suitable for steel structures or piping exposed to high-corrosion environments C5I or C5M (ISO 12944-2). It complies with the compositional requirements of SSPC Paint 20 Level 1, ISO 12944-5 and AS/NZS 3750.15 1994. Parameters on this page: volume solids 67 ± 2%, dry film thickness 50–90 µm, theoretical spreading rate 13.4–7.4 m²/L. Comparable models from the same brand: Resist 60 Inorganic Zinc Silicate Primer 5DG, Resist 65 Inorganic Zinc Silicate Primer, Resist 78 KV Inorganic Zinc Silicate Primer.

Parameter source: JOTUN original technical data sheet (TDS) “Resist 86 Inorganic Zinc Silicate Primer”; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids67 ± 2%
Dry Film Thickness50–90 µm
Theoretical Spreading Rate13.4–7.4 m²/L
VOC448 g/L (China)
Density / Specific Gravity2.6 kg/L
Number of ComponentsTwo-component
Flash Point14 °C
ThinnerJOTUN Thinner No. 4 / Jotun Thinner No. 25…
Mixing Ratio8 parts : 2.6 parts (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer

FAQ

How many components does Resist 86 have?
Resist 86 is a two-component product; use after mixing in the ratio given in the "Application Data" table on this page.
What is the mixing ratio of Resist 86?
The mixing ratio of Resist 86 is 8 parts : 2.6 parts (by volume).
What dry film thickness is typically applied for Resist 86?
The conventional dry film thickness of Resist 86 is 50–90 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Resist 86?
The theoretical spreading rate of Resist 86 is 13.4–7.4 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Resist 86?
The volume solids of Resist 86 is 67 ± 2%.
What is the VOC of Resist 86?
The VOC of Resist 86 is 448 g/L (China).
What thinner is used for Resist 86?
Recommended thinner for Resist 86: JOTUN Thinner No. 4 / Jotun Thinner No. 25 JOTUN No. 25…
What is the flash point of Resist 86?
The flash point of Resist 86 is 14 °C; storage, transport and application shall be carried out in accordance with the product safety data sheet.
How long does Resist 86 take to dry?
Drying time of Resist 86 under standard conditions: touch dry 1 h; actual results are affected by temperature, film thickness and ventilation.
Which standards apply to Resist 86?
As recorded in the technical data on this page: industrial protective coatings: suitable for steel structures or piping exposed to the highly corrosive environment C5I or C5M (ISO 12944-2); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Resist 86 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Resist 86

Product description

This is a two-component, moisture-curing inorganic zinc silicate coating with fast curing and high zinc content.

It complies with the compositional requirements of SSPC Paint 20 Level 1, ISO 12944-5 and AS/NZS 3750.15 1994. Excellent anticorrosive properties; may be used alone or in combination with other coatings. Heat resistance up to 540 °C. Used as a primer in atmospheric environments, in a coating system or alone. Suitable only for properly prepared carbon steel substrates. The zinc dust in this product complies with ASTM D520, Type II.

Typical Use

Industrial protective coatings:

Suitable for steel structures or piping exposed to high-corrosion environments C5I or C5M (ISO 12944-2). Recommended for offshore environments, such as refineries, power stations, bridges, buildings, mining equipment and general structural steel. Specifically used as a primer in combination with other coatings for improved durability.

Others

Approvals and Certificates

Pre-qualified in selected coating systems according to Norsok M-501. Suitable for bolted and riveted high-strength friction grip connections:

Meets the requirements of Class B, Appendix A (slip coefficient and tension creep resistance) of the Research Council on Structural Connections (RCSC).

Other certificates and approvals are available on request.

Colour

Grey-green, Grey

Product Data

PropertyTest / StandardDescription
Volume SolidsOCCA Monograph No. 467± 2 %
Gloss (GU 60°)ISO 2813Matt (0–35)
Flash PointISO 3679 Method 114 °C
DensityTheoretical Value2.6 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113US EPA Method 24455 g/L
Hong KongAir Pollution Control (VOC) Regulation455 g/L
EUEuropean Paint Directive 2004/42/CECalculation509 g/L
ChinaMandatory national standard of ChinaGB 30981.2-2025448 g/L

Coating hazards GB 30981.2-S-Pb≤1000-NC. The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness50–90 µm
Wet Film Thickness75–135 µm
Theoretical Spreading Rate13.4–7.4 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1); surface roughness fine to medium G (ISO 8503-2)

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by air spray or airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. To avoid settling of the zinc dust, mechanical agitation during application is recommended.

Mixing Ratio (by Volume)

Resist 86 Comp A — Inorganic Zinc Silicate Primer 0KH, Component A8 parts
Jotun Zinc 100 Comp B — JOTUN Inorganic Zinc Silicate Primer/Tank Coating Series, Component B2.6 parts

Component A is a liquid and Component B is dry zinc dust. Shake Component A thoroughly before use. While stirring mechanically, slowly pour the zinc dust into the liquid. Stir until free of lumps and strain through a 60-mesh screen.

Thinner / Cleaning Solvent

ThinnerJOTUN Thinner No. 4 / Jotun Thinner No. 25, JOTUN Thinner No. 25 / Jotun Thinner No. 4
JOTUN Thinner No. 4To accelerate evaporation

Jotun Thinner No. 25

JOTUN Thinner No. 25To slow evaporation

JOTUN Thinner No. 28 may be used in place of JOTUN Thinner No. 4 as a fast-evaporating thinner.

Normally no thinning is required. Consult the local JOTUN representative for application under extreme conditions. When thinning, do not exceed the requirements of local environmental regulations. Note: where the Korean VOC regulation Clean Air Conservation Act and its corresponding thinning limit differ from the recommended thinning volume, the former shall prevail.

JOTUN Thinner No. 17 may be used as an alternative cleaner.

Airless Spray Guidance

Nozzle tip size (inch/1000):17-21
Nozzle pressure (minimum):100 bar/1400 psi

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry1 h30 min15 min13 min
Walk-on Dry1.5 h45 min30 min25 min
Minimum recoat interval18 h13 h4 h1.5 h
Dry/cured to service18 h13 h4 h1.5 h

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

The average dry film thickness, drying and curing times during application and curing, and the recoat interval of the inorganic zinc silicate should be measured at controlled temperature and 70% relative humidity. Higher relative humidity increases the curing rate.

If the relative humidity during application is below 60%, curing of the coating will be affected. Jotun Zinc 100 LHA may be used to accelerate curing. For more information, refer to the application guide.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Pot Life8 h

Heat Resistance

Temperature

ContinuousPeak
Drying, atmospheric400°C540 °C

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

At a dry film thickness of 50 µm with a suitable topcoat, the product withstands prolonged dry heat of 400 °C to 540 °C (i.e. 1004 °F). For the corresponding temperatures, the recommended inorganic zinc silicate is Jotatemp 540 Zinc for better durability.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Subsequent CoatEpoxy, silicone acrylic

Typical Packaging Sizes

VolumeContainer Size
(L)
Resist 86 Comp A — Inorganic Zinc Silicate Primer 0KH, Component A810
Jotun Zinc 100 Comp B — JOTUN Inorganic Zinc Silicate Primer/Tank Coating Series, Component B2.620

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Resist 86 Comp A — Inorganic Zinc Silicate Primer 0KH, Component A6 months
Jotun Zinc 100 Comp B — JOTUN Inorganic Zinc Silicate Primer/Tank Coating Series, Component B48 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Environmental documentation

This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.

EPDs are available at www.epd-norge.no

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, zinc-rich primer

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery