Penguard WF Water-borne Epoxy Primer WF is a water-borne paint used as a primer. Recommended for offshore environments such as refineries, power stations, bridges, buildings and mining equipment. In atmospheric environments, it can be used as a primer, intermediate coat, topcoat or single-coat system. Parameters on this page: volume solids 51 ± 2%, dry film thickness 75–150 µm, theoretical spreading rate 6.8–3.4 m²/L. Comparable products from the same brand: Penguard E33 WF II Water-borne Fast-drying Epoxy Primer E33 II, Penguard Express ZP WF Water-borne Fast-drying Epoxy Zinc Phosphate, Barrier 80 WF Water-borne Epoxy Zinc-rich Primer.
Parameter source: JOTUN original technical data sheet (TDS) "Penguard WF Water-borne Epoxy Primer WF"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 51 ± 2% |
|---|---|
| Dry Film Thickness | 75–150 µm |
| Theoretical Spreading Rate | 6.8–3.4 m²/L |
| VOC | GB/T 23986-2009 10.4 69 g/L (China) |
| Density / Specific Gravity | 1.3 kg/L |
| Number of Components | Two-component |
| Flash Point | 62 °C |
| Mixing Ratio | 2 parts : 1 part : 2 parts : 1 part (by volume) |
| Gloss | Matt (0–35) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Penguard WF
This product is a two-component water-borne epoxy anti-corrosive paint. It is a general-purpose fast-drying product containing flash rust inhibitor. It cures at temperatures as low as 5 °C. It is specifically for new construction projects requiring fast drying and recoat time requirements. In atmospheric environments, it can be used as a primer, intermediate coat, topcoat or single-coat system. Suitable for properly prepared carbon steel, aluminium, concrete and galvanized steel substrates. A curing agent suitable for application on low-temperature substrates is available.
Suitable for steel structures and pipelines in highly corrosive environments. Recommended for offshore environments such as refineries, power stations, bridges, buildings and mining equipment. Suitable for recoating with water-borne acrylic, water-borne epoxy and suitable solvent-borne coatings.
Others
The product may contribute to green building standard credits; see the Green Building Standards section.
Complies with Estidama VOC content requirements. Complies with GSAS VOC content requirements. Complies with "China Environmental Labelling" requirements. Certified by fire test for use under SteelMaster 1200WF. Other certificates and approvals available upon request.
Grey, Grey XO, Red
Property Test/Standard Description
Ambient-curing
| Volume Solids | ISO 3233 | 51± 2 % |
| Gloss (GU 60°) | ISO 2813 | Matt (0–35) |
| Flash Point | ISO 3679 Method 1 | 62 °C |
| Density | Theoretical Value | 1.3 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 66 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | Calculation | 66 g/L |
| EU | European Paint Directive 2004/42/CE | Calculation | 64 g/L |
| China | GB 30981-2020 Limit of harmful substances of industrial protective coatings | GB/T 23986-2009 10.4 69 g/L |
Winter grade
| Volume Solids | ISO 3233 | 51± 2 % |
| Flash Point | ISO 3679 Method 1 | 62 °C |
| Density | Theoretical Value | 1.3kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 69 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | Calculation | 69 g/L |
| EU | European Paint Directive 2004/42/CE | Calculation | 67 g/L |
| EU | ISO 11890 | 65 g/L | |
| China | GB 30981-2020 Limit of harmful substances of industrial protective coatings | GB/T 23986-2009 10.4 57 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
VOC content based on grey paint.
Typical recommended specification range
| Dry Film Thickness | 75–150 µm |
| Wet Film Thickness | 145–295 µm |
| Theoretical Spreading Rate | 6.8–3.4 m²/L |
| Dry Film Thickness | 75–150 µm |
| Wet Film Thickness | 145–295 µm |
| Theoretical Spreading Rate | 6.8–3.4 m²/L |
Surface Preparation
| Substrate | Minimum | Recommended |
| Carbon Steel | St 2 (ISO 8501-1) | Sa 2½ (ISO 8501-1) |
| Aluminium | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” |
to produce scratch marks on the surface.
| Galvanised steel | The surface should be clean, dry and have a suitable profile | Sweep blast with a non-metallic abrasive to produce a clean, |
| ° | a rough and uniform surface. | |
| Concrete | Curing time of at least 4 weeks. Maximum moisture 5%. For existing | Curing time of at least 4 weeks. Maximum moisture 5%. Seal with |
| Concrete surfaces: sanding, needle gun and mechanical grinding | Closed-circuit blasting, diamond grinding and other suitable methods | |
| and similar, by mechanical treatment | to treat the surrounding concrete surface to remove laitance. |
This product may be applied by the following methods
| Spray: | Apply by airless spray. |
| Brush: | Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. |
| Roller: | May be used for small areas, but not recommended as the first primer coat. However, with roller application, take care to apply sufficient material to achieve the specified dry film thickness. |
| Penguard WF Comp A | 2 parts |
| Water-Borne Epoxy Primer WF, Component B | 1 part |
| Penguard WF Comp A | 2 parts |
| Water-Borne Epoxy WF, Component B (Winter Grade) | 1 part |
| Thinner: | Fresh water |
| Cleaner: | Jotun Thinner No. 17 / Jotun Thinner No. 4 |
JOTUN Thinner No. 28 may replace JOTUN Thinner No. 4 as a cleaner.
When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements
In China, the cleaning solvent must comply with GB 38508-2020
| Nozzle tip size (inch/1000): | 19-23 |
| Nozzle pressure (minimum): | 150 bar/2100 psi |
| Substrate Temperature | 5 °C | 10 °C | 23 °C | 40 °C |
| Ambient-curing | ||||
|---|---|---|---|---|
| Touch Dry | 1.5 h | 30 min | ||
| Walk-on Dry | 10 h | 4 h | ||
| Minimum recoat interval | 4.5 h | 2.5 h | ||
| Dry/cured to service | 7 days | 5 days | ||
| Winter grade | ||||
| Touch Dry | 1.5 h | 1 h | ||
| Walk-on Dry | 3 days | 1 day | 8 h | |
| Minimum recoat interval | 15 h | 5 h | 3.5 h | |
| Dry/cured to service | 21 days | 14 days | 7 days | |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 10 °C | 23 °C | 40 °C |
| Ambient-curing | |||
|---|---|---|---|
| Induction Time | 15 min | ||
| Pot Life | 1.5 h | 1 h | |
| Winter grade | |||
| Pot Life | 1 h | ||
The pot life of the product is clearly visible.
This is the induction time for the standard product. The winter-grade product can be used immediately after thorough stirring.
Temperature
| Continuous | Peak | |
| Drying, atmospheric | 120°C | 140 °C |
Withstands peak temperatures for a maximum of one hour.
At the above temperatures, protective performance is unaffected, but appearance may be affected.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Inorganic zinc shop primer, epoxy, modified epoxy, zinc-rich epoxy, zinc silicate |
| Subsequent coat: | Epoxy, acrylic, polyurethane, polysiloxane |
| Volume | Container Size | |
| (L) | ||
| Penguard WF Comp A | 10 | 20 |
| Water-Borne Epoxy Primer WF, Component B | 5 | |
| Water-Borne Epoxy WF, Component B (Winter Grade) | 5 | |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Penguard WF Comp A | 12 months |
| Water-Borne Epoxy Primer WF, Component B | 24 months |
| Water-Borne Epoxy WF, Component B (Winter Grade) | 24 months |
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
LEED®v4 (2013)
| EQ credit | Low-emitting materials |
|---|
VOC content of industrial maintenance coatings (250 g/L) (CARB (SCM) 2007), with VOC emission between 0.5–5.0 mg/m³ (CDPH Standard Method 1.2).
| MR credit | Analysis, disclosure and optimisation of building products — material ingredients, Option 2: material ingredient optimisation, internationally acceptable alternative compliance path — REACH optimisation: using only chemical ingredients not exceeding 100 ppm, and free from substances on the REACH Authorisation List Annex XIV, Restriction List Annex XVII and the supplementary list of substances of very high concern. |
|---|
LEED® (2009)
IEQ credit 4.2: VOC requirements of the green label standard GC-03, 1997, BREEAM® International (2016)
Mat 01: Type III EPD for the specific product (ISO 14025; 21930, EN 15804).
BREEAM® International (2013)
The product is tested by RISE Research Institutes of Sweden / Eurofins SP Technical Research Institute of Sweden, according to California Department of Public Health (CDPH) Standard Method v1.1-2010.
EPDs are available at www.epd-norge.no
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.