Jotacote Universal S120 Environment-friendly Solvent-free Universal Epoxy Primer S120 is an epoxy coating used as a primer. Recommended for most areas of suitably prepared substrates in industrial new construction, large maintenance projects and newbuildings. Jotacote Universal S120 is a high-build, solvent-free universal primer providing high anticorrosive performance for atmospheric and immersion service. Parameters on this page: volume solids 97 ± 2%; dry film thickness 150–500 µm; theoretical spreading rate 6.5–1.9 m²/L. Comparable products from the same brand: Balloxy BT Modified Epoxy Primer BT, Jota EP15 Fast-drying Epoxy Primer, Jota EP15P Fast-drying Epoxy Primer EP15P.
Source: JOTUN original technical data sheet (TDS) 'Jotacote Universal S120 Environment-friendly Solvent-free Universal Epoxy Primer S120'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 97 ± 2% |
|---|---|
| Dry Film Thickness | 150–500 µm |
| Theoretical Spreading Rate | 6.5–1.9 m²/L |
| VOC | 8 g/L (US) |
| Density / Specific Gravity | 1.6 kg/L |
| Number of Components | Two-component |
| Flash Point | 100 °C |
| Thinner | Jotun Thinner No. 17 |
| Mixing Ratio | 2.5 parts : 1 part (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Jotacote Universal S120
Jotacote Universal S120 is a high-build, solvent-free universal primer providing high anticorrosive performance for atmospheric and immersion service. It is a two-component polyamine-cured epoxy coating based on patented Covallox™ technology. Jotacote Universal S120 is suitable for applications requiring low VOC emission and long-term steel protection. It is approved for use as a single-coat system in ballast tanks.
Suitable for steel structures exposed to atmospheric corrosion and immersed conditions. Recommended for most areas of properly prepared substrates in new industrial construction, major maintenance projects and newbuildings. Abrasive blasting is recommended to achieve optimum adhesion and durability. Passed PSPC crossover testing and suitable for use over various shop primers.
Others
Pre-qualified according to NORSOK M-501 in selected coating systems. As a primer in specific coating systems, its performance has been tested according to ISO 12944 and meets requirements up to corrosivity category CX.
As an intermediate coat in a specific system, tested to ISO 12944 CX.
Tested as a primer in specific systems according to ISO 12944, up to category IM4.
Certified per IMO Res. MSC.215(82) for ballast tank PSPC standard. Certified to IMO 2010 FTP Code — low flame spread requirements. For details, consult the Jotun representative.
Other certificates and approvals are available on request.
Light yellow, light red, grey, light green, light grey
| Property | Test / Standard | Description |
| Volume Solids | ISO 3233 | 97± 2 % |
| Gloss (GU 60°) | ISO 2813 | Gloss (70–85) |
| Flash Point | ISO 3679 Method 1 | 100 °C |
| Density | Theoretical Value | 1.6 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 8 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | Calculation | 8 g/L |
| EU | European Paint Directive 2004/42/CE | Calculation | 8 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
Typical recommended specification range
| Dry Film Thickness | 150–500 µm |
| Wet Film Thickness | 155–515 µm |
| Theoretical Spreading Rate | 6.5–1.9 m²/L |
Surface Preparation
| Substrate | Minimum | Recommended |
| Carbon Steel | St 2 (ISO 8501-1) | Sa 2½ (ISO 8501-1) |
| Aluminium | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” |
to produce scratch marks on the surface.
| Galvanised steel | The surface should be clean, dry and have a suitable profile | Sweep blast with a non-metallic abrasive to produce a clean, |
| ° | a rough and uniform surface. | |
| Shop-primed Steel | Dry, clean, intact shop primer | Sweep blast or abrasive blast clean at least 70% of the area to Sa 2 (ISO 8501-1) |
| Stainless steel | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” |
Coated surfaces: clean, dry and sound compatible primer. Sa 2½ (ISO 8501-1)
The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.
This product may be applied by the following methods
| Spray | Apply by airless spray. |
|---|
| Brush: | Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. | |
| Roller: | Suitable for small areas. | Not recommended for the first primer coat. Take care to achieve the specified dry film thickness. |
| Jotacote Universal S120 Comp A — Eco-Friendly Solvent-Free General-Purpose Epoxy Primer S120, Component A | 2.5 parts |
| Jotacote Universal S120 Standard Comp B — Eco-Friendly Solvent-Free General-Purpose Epoxy Primer S120, Component B | 1 part |
| Thinner: | Jotun Thinner No. 17 |
| Cleaner: |
When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements
| Nozzle tip size (inch/1000): | 17-25 |
| Nozzle pressure (minimum): | 180 bar / 2600 psi |
| Substrate Temperature | 10 °C | 23 °C | 40 °C |
| Touch Dry | 17 h | 7 h | 3 h |
| Walk-on Dry | 23 h | 9 h | 4 h |
| Minimum recoat interval | 21 h | 8 h | 4 h |
| Dry/cured to immersion | 3 days | 2 days | 1 day |
| Dry/cured to service | 12 days | 7 days | 3 days |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to immersion: the minimum time before the coating can be permanently immersed in sea water.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 23 °C |
| Pot Life | 1 h |
Lowering the temperature prevents the paint from expanding.
Temperature
| Drying, atmospheric | Continuous 120 °C | Peak 140 °C |
| Immersed, sea water | 50 °C | 60 °C |
Withstands peak temperatures for a maximum of one hour.
At the above temperatures, protective performance is unaffected, but appearance may be affected.
Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Inorganic zinc silicate shop primer, epoxy, modified epoxy, zinc-containing epoxy |
| Subsequent coat: | Acrylic, alkyd, epoxy, polyurethane, polysiloxane, modified epoxy, vinyl epoxy |
| Volume | Container Size | |
| (L) | ||
| Jotacote Universal S120 Comp A — Eco-Friendly Solvent-Free General-Purpose Epoxy Primer S120, Component A | 12.5 | 20 |
| Jotacote Universal S120 Standard Comp B — Eco-Friendly Solvent-Free General-Purpose Epoxy Primer S120, Component B | 5 | |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
Jotacote Universal S120 Comp A, 12 months, Environment-friendly Solvent-free Universal Epoxy Primer S120 Component A. Jotacote Universal S120 Standard Comp B, 24 months, Environment-friendly Solvent-free Universal Epoxy Primer S120 Component B
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.
EPDs are available at www.epd-norge.no
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.