← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Hardtop Metallic Uni Polyurethane Metallic Topcoat

Quick Specs

Hardtop Metallic Uni Polyurethane Metallic Topcoat is a polyurethane coating used as a topcoat. Industrial protective coatings: recommended for offshore environments such as refineries, power stations, bridges and buildings. It is a two-component chemically cured aliphatic acrylic polyurethane coating. Parameters on this page: volume solids 57 ± 2%, dry film thickness 40–60 µm, theoretical spreading rate 14.3–9.5 m²/L. Comparable products of the same brand: Hardtop AX K II Aliphatic Polyurethane Topcoat AX K II, Hardtop AX Aliphatic Polyurethane Topcoat AX, Hardtop Alfa Anti-mould Polyurethane Topcoat.

Parameter source: JOTUN manufacturer's Technical Data Sheet (TDS) "Hardtop Metallic Uni Polyurethane Metallic Topcoat"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids57 ± 2%
Dry Film Thickness40–60 µm
Theoretical Spreading Rate14.3–9.5 m²/L
VOC365 g/L (China)
Density / Specific Gravity1.2 kg/L
Number of ComponentsTwo-component
Flash Point24 °C
ThinnerJotun Thinner No. 10 dilution ratio…
Mixing Ratio7 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Topcoat, Polyurethane

FAQ

How many components does Hardtop Metallic Uni have?
Hardtop Metallic Uni is a two-component product; mix according to the mixing ratio in the Application Data table on this page before use.
What is the mixing ratio of Hardtop Metallic Uni?
The mixing ratio of Hardtop Metallic Uni is 7 parts : 1 part (by volume).
What dry film thickness is typically applied for Hardtop Metallic Uni?
Hardtop Metallic Uni is typically applied at a dry film thickness of 40–60 µm, subject to the coating system and design requirements.
What is the theoretical spreading rate of Hardtop Metallic Uni?
The theoretical spreading rate of Hardtop Metallic Uni is 14.3–9.5 m²/L; actual consumption depends on substrate roughness, application loss and colour hiding power.
What are the volume solids of Hardtop Metallic Uni?
The volume solids of Hardtop Metallic Uni are 57 ± 2%.
What is the VOC of Hardtop Metallic Uni?
The VOC of Hardtop Metallic Uni is 365 g/L (China).
Which thinner is used with Hardtop Metallic Uni?
Recommended thinner for Hardtop Metallic Uni: Jotun Thinner No. 10 dilution ratio….
What is the flash point of Hardtop Metallic Uni?
The flash point of Hardtop Metallic Uni is 24°C; storage, transport and application follow the product Safety Data Sheet.
How long does Hardtop Metallic Uni take to dry?
Drying time of Hardtop Metallic Uni under standard conditions: touch dry 1.5 h; actual values depend on temperature, film thickness and ventilation.
Which standards apply to Hardtop Metallic Uni?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 3679 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Hardtop Metallic Uni be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Hardtop Metallic Uni

Product description

This is a two-component chemically curing aliphatic acrylic polyurethane coating. A range of metallic topcoats with excellent gloss retention is available. This is an aluminium micaceous iron oxide product. The product has a uniform appearance and good application properties. It is used as a topcoat in atmospheric environments.

Typical Use

Industrial protective coatings:

Recommended for offshore environments such as refineries, power stations, bridges and buildings. Widely suitable for industrial structures.

Others

Colour

Selected metallic colours preferred.

Different application methods, dry film thickness, temperature, humidity and substrate may produce different results.

Due to technical limitations, exact matching of metallic topcoat colours is not possible

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323357± 2 %
Flash PointISO 3679 Method 124 °C
DensityTheoretical Value1.2 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation383 g/L
Hong KongAir Pollution Control (VOC) RegulationCalculation383 g/L
EUEuropean Paint Directive 2004/42/CECalculation383 g/L
ChinaMandatory national standard of ChinaGB 30981.2-2025365 g/L
Coating hazards GB30981.2-S-Pb≤1000-NC

The data listed are based on factory batch production and may vary slightly with colour.

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness40–60 µm
Wet Film Thickness70–105 µm
Theoretical Spreading Rate14.3–9.5 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Coated surfaceA clean, dry and sound compatible primer.

Application

Application Methods

This product may be applied by the following methods

SprayApply by air spray or airless spray.

Different application methods or techniques may produce different metallic effects.

Mixing Ratio (by Volume)

Hardtop Metallic Uni Comp A — Polyurethane Metallic-Effect Topcoat, Component A7 parts
Hardtop Metallic Uni Comp B — Polyurethane Metallic-Effect Topcoat, Component B1 part

Thinner / Cleaning Solvent

ThinnerJotun Thinner No. 10. Changes in thinning ratio may affect the orientation of aluminium particles in the film and the brightness of the film.

Airless Spray Guidance

Nozzle tip size (inch/1000):13-19
Nozzle pressure (minimum):150 bar/2100 psi

Air spray guidance

Nozzle tip size:HVLP: 13–15 (inch/1000) / pressure pot: 1.3–1.5 (mm)
Nozzle pressure (minimum):HVLP: 2.1 bar/30 psi / pressure pot: 2.1 bar/30 psi

Fluctuations in gun tip pressure may affect the orientation of aluminium flakes and the brightness of the film.

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry1.5 h1 h45 min20 min
Walk-on Dry12 h8 h4.5 h2 h
Minimum recoat interval12 h8 h4.5 h2 h
Dry/cured to service20 days15 days7 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Pot Life3 h

Heat Resistance

Temperature

ContinuousPeak
Drying, atmospheric120°C140 °C

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Epoxy, zinc epoxy, modified epoxy, polyurethane
Subsequent coat:Polyurethane

Typical Packaging Sizes

VolumeContainer Size
(L)
Hardtop Metallic Uni Comp A — Polyurethane Metallic-Effect Topcoat, Component A17.520
Hardtop Metallic Uni Comp B — Polyurethane Metallic-Effect Topcoat, Component B2.53

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Hardtop Metallic Uni Comp A — Polyurethane Metallic-Effect Topcoat, Component A24 months
Hardtop Metallic Uni Comp B — Polyurethane Metallic-Effect Topcoat, Component B48 months

Recommended storage temperature is 5–40°C.

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — topcoat, polyurethane coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery