Hempel's Alkyd High-build Primer 13200 is an alkyd coating used as a primer. As the general-purpose primer of the Hempel's alkyd series, applied to steel in mildly to moderately corrosive atmospheric environments. Complies with EU Directive 2004/42/EC 'the Paints Directive on limiting volatile organic compounds: subcategory i'. Parameters on this page: volume solids 48 ± 2%; dry film thickness 75 µm; theoretical spreading rate 6.3 m²/L. Comparable products from the same brand: Hempel's Alkyd Anti-rust Primer 12050, Hempel's Fibre-containing Inorganic Zinc-rich Paint 15750, Hempel's Zinc-rich Primer 16490.
Source: HEMPEL original technical data sheet (TDS) 'Hempel's Alkyd High-build Primer 13200'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 48 ± 2% |
|---|---|
| Dry Film Thickness | 75 µm |
| Theoretical Spreading Rate | 6.3 m²/L |
| VOC | 406 g/L (China) |
| Density / Specific Gravity | 1.3 kg/L |
| Number of Components | — |
| Flash Point | 39°C |
| Thinner | HEMPEL's Thinner 08080 |
| Colour / Appearance | Beige 22430 |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
13200
Hempel's Alkyd High-build Primer 13200 is a polyurethane-modified, fast-drying alkyd primer.
Complies with EU Directive 2004/42/EC 'the Paints Directive on limiting volatile organic compounds: subcategory i'.
As the general-purpose primer of the Hempel's alkyd series, applied to steel in mildly to moderately corrosive atmospheric environments.
| Product safety | Flash point 39 °C |
|---|
| Regulations | Value |
| European Union | 406 g/L |
| USA (coatings) | 406 g/L |
| USA (regulatory) | 406 g/L |
| Canada | 406 g/L |
| China | 406 g/L |
| Hong Kong | 406 g/L |
| South Korea | 406 g/L |
Subject to specific legislation; see the explanatory notes on the Hempel website hempel.com or your local Hempel website. VOC values may vary with colour; refer to Section 9 of the Safety Data Sheet. ªEU Directive 2004/42/CE. This product complies with the VOC requirements of national mandatory or recommended standards; consult the company representative for details.
Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.
For professional use only.
| Product code | 13200 |
|---|---|
| Standard colour* / code | Beige 22430 |
| Gloss | Flat |
| Volume solids | 48 ± 2% |
| density | 1.3 kg/L |
| Recommended dry film thickness | 75 µm |
13200
Stir thoroughly before use.
| Thinner | HEMPEL's Thinner 08080 |
|---|---|
| Cleaning solvent | HEMPEL's Thinner 08080 |
| Tools | Maximum thinning volume | Application parameters |
| Airless Spray | 5% | Nozzle pressure: 20 MPa; tip size: 0.53–0.58 mm |
| Brush | 5% | Not applicable. |
If brush or roller application is used, several coats may be required to achieve the specified dry film thickness. Spray parameters are indicative and may be adjusted to suit site conditions. Pressure figures apply to the material at 20 °C. (*For other application methods, consult the company representative.)
| Specification range | Low | High | Recommended |
| Wet Film Thickness | 105 µm | 168 µm | 158 µm |
| Theoretical Spreading Rate | 10 m²/L | 5.9 m²/L | 6.3 m²/L |
Depending on the end use and service area, the product may be specified at film thicknesses other than those indicated. This will alter the spreading rate, drying and curing times and recoat interval. To achieve optimum performance, avoid excessive film thickness.
| Surface temperature | 20°C |
| Touch Dry | 120 min |
| Surface Dry | 120 min |
Measured at 75 µm dry film thickness under standard conditions; see Hempel's explanatory notes.
Hempel's specifications supersede all guidance shown in the recoat table.
| Product name | 10°C | 20°C | 30°C | |
| Atmospheric, moderate | ||||
|---|---|---|---|---|
| Hempel's Alkyd High-build Primer 13200 | Minimum | 10 h | 5 h | 4 h |
| Maximum | 18 days | 10 days | 7½ days | |
| HEMPEL Alkyd Enamel 52140 | Minimum | 10 h | 5 h | 4 h |
| Maximum | 18 days | 10 days | 7½ days | |
For products of the same generic chemical composition, recoat times are for reference only.
For further information, refer to Hempel's specifications.
- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.
13200
| Ambient temperature | 25°C |
|---|---|
| Product | 60 months |
When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. For advice, consult Hempel.
- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| GWP (Global Warming Potential) | 8.2 g CO₂e/m² |
|---|
Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².
The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.
Calculated based on the standard colours defined in this PDS. Values may vary with colour.
| Number | Document description | Location/Notes |
| 3. | PDS | This document |
datasheet, which is also available for download at www.hempel.com.
For further information, refer to the Hempel website (https://www.hempel.com/service-and-support/technical-guidelines) or your local Hempel website:
- Application methods - General application guide. This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):
| 1. | Technical declaration | Provides one-off specific advice for the requirements of a specific project |
| 2. | Specifications | Issued for specific projects only |
| 4. | Explanatory notes to the PDS | Available for download at www.hempel.com, containing information related to product test parameters |
| 5. | Application guide | If available, provided at www.hempel.com |
| 6. | General technical guidelines (e.g. application and surface preparation) |
If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.
The factory item numbers of Hempel's Alkyd High-build Primer 13200 are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.
| Item No. | Colour / colour code | Packaging Specifications |
|---|---|---|
| 13200-11750 OFF WHITE | — | 20 L |
This model has a total of1item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.