China-based coatings exporter — industrial & marine protective coatings from China's production bases

Interzinc 72 Epoxy Zinc-rich Primer

Quick Specs

Interzinc 72 Epoxy Zinc-rich Primer belongs to zinc-rich primers, epoxy coating system. As a shop or field-applied primer for high-performance coating systems to protect steel in aggressive environments (e.g., offshore facilities, refineries, petrochemical and chemical plants, power stations, bridges, pulp and paper mills). A two-component, metallic zinc-rich epoxy primer that provides excellent corrosion protection both as a single coat and as a primer in high-performance systems. Overapplication of Interzinc 72 will extend the minimum recoat time and handling time, adversely affecting long-term recoatability. Parameters on this page: dry film thickness 50–75 µm (2–3 mils), theoretical spreading rate 8 m²/L, number of components two-component.

Parameter source: AkzoNobel AKZONOBEL original technical data sheet (TDS) 'Interzinc 72 Epoxy Zinc-rich Primer'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids60%
Dry Film Thickness50–75 µm (2–3 mils)
Theoretical Spreading Rate8 m²/L
VOC149 g/kg EU solvent emission directive content (EU Council Directive 2010/75…
Density / Specific Gravity2.77 kg/L (23.1 lb/gal)
Number of ComponentsTwo-component
ThinnerDo not exceed the thinning limits of local environmental regulations
Mixing Ratio4.0 parts : 1.0 part (by volume)
Colour / AppearanceGrey, INTERZINC 72

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer, Epoxy

FAQ

How many components does Interzinc 72 have?
Interzinc 72 is a two-component product; mix according to the mixing ratio in the 'Application Data' table on this page before use.
What is the mixing ratio of Interzinc 72?
Mixing ratio for Interzinc 72 is 4.0 part : 1.0 part (by volume).
What is the typical dry film thickness for Interzinc 72?
Typical dry film thickness for Interzinc 72 is 50–75 µm (2–3 mils), depending on the coating system and design requirements.
What is the theoretical spreading rate of Interzinc 72?
Theoretical spreading rate of Interzinc 72 is 8 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Interzinc 72?
Volume solids of Interzinc 72 is 60%.
What is the VOC of Interzinc 72?
VOC of Interzinc 72 is 149 g/kg EU Solvent Emissions Directive content (Council Directive 2010/75….
What is the gloss of Interzinc 72?
Gloss of Interzinc 72 is matt.
What thinner is used for Interzinc 72?
Recommended thinner for Interzinc 72: dilution shall not exceed local environmental regulation limits.
How is Interzinc 72 applied?
Application method for Interzinc 72: airless spray, air spray, brush and roller; drying time and recommended topcoat recoating interval; surface preparation and the coating system are as described on this page.
Which standards apply to Interzinc 72?
As recorded in the technical data on this page: GB 30981.2 (see the application instructions on this page); before painting, all surfaces shall be assessed and prepared in accordance with ISO 8504-1. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Interzinc 72 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product description

A two-component, metallic zinc-rich epoxy primer that provides excellent anticorrosive performance both as a single coat and as a primer in high-performance systems. Zinc dust content in the dry film is 90%.

Intended use

As a shop or field-applied primer for high-performance coating systems to protect steel in aggressive environments (e.g. offshore installations, refineries, petrochemical and chemical plants, power stations, bridges, pulp and paper mills).

Application data

ColourGrey, INTERZINC 72
GlossMatt
Volume Solids60%
Typical thicknessDry film thickness 50–75 µm (2–3 mils) corresponds to wet film thickness 83–125 µm (3.3–5 mils)
Theoretical Spreading Rate8 m²/L at 75 µm dry film thickness and the stated volume solids; 321 ft²/US gal at 3 mil dry film thickness and the stated volume solids
Practical Spreading RateAllowing for a suitable loss factor
Application MethodsSuitable for airless spray, air spray, brush, roller. Drying time; recommended topcoat recoat interval
TemperatureSurface DryHard DryMinimumMaximum
10°C (50°F)45 min6 h8 hUnlimited¹
15°C (59°F)35 min4 h6 hUnlimited¹
25°C (77°F)25 min90 min4 hUnlimited¹
40°C (104°F)20 min45 min2 hUnlimited¹

¹ See Definitions and Abbreviations from the International Paint Protective Coatings division.

Regulatory compliance data

Flash point (typical)Component A 32 °C (90 °F); Component B 33 °C (91 °F); Mixed 32 °C (90 °F)
Product weight2.77 kg/L (23.1 lb/gal)
Volatile Organic Compounds149 g/kg EU Solvent Emissions Directive content (Council Directive 2010/75/EU) Coating hazard GB 30981.2-S-Pb≤1000-NC complies with GB 30981.2-2025. For more detailed information, see the "Product Characteristics" section.

Surface Preparation

All surfaces to be painted must be clean, dry and free of contaminants. Before painting, all surfaces must be assessed and prepared in accordance with ISO 8504-1.

Oil and grease must be removed in accordance with the SSPC-SP1 solvent cleaning standard.

Abrasive blasting: blast clean to Sa2½ (ISO 8501-1:2007) or SSPC-SP6 standard. If oxidation occurs between blast cleaning and application of Interzinc 72, the surface shall be re-blast cleaned to the specified visual standard.

Surface defects exposed by abrasive blasting must be ground, filled or treated by another suitable method.

Recommended surface roughness 40–75 µm (1.5–3.0 mils).

Shop-primed steel structures: Interzinc 72 is suitable for application to steel components newly coated with zinc silicate shop primer.

If the zinc dust shop primer shows large-scale scattered breakdown or heavy zinc salts, the entire area must be fully sweep blasted.

Not suitable for recoating other types of shop primer; remove them completely by abrasive blasting.

Welds and damaged areas must be blast cleaned to Sa 2½ (ISO 8501-1:2007) or SSPC-SP6.

Application

MixingThis product is supplied in two containers forming one unit. Mix the two components in the specified ratio in one operation. Once mixed, use within the specified pot life.

(1) Stir the base (Component A) with a power mixer.

(2) Mix all of the curing agent (Component B) with the base (Component A) and stir thoroughly with a power mixer.

Mixing ratio4.0 parts : 1.0 part (by volume)
Pot life10°C (50°F)15°C (59°F)25°C (77°F)40°C (104°F)
12 h10 h8 h5 h
Suitable for airless sprayRecommended: nozzle diameter 0.43–0.53 mm (17–21 thousandths of an inch); total paint pressure at the nozzle not less than 176 kg/cm² (2503 psi)
Air SprayMay require thinningSpray gunDeVilbiss MBC or JGA
Air nozzle704 or 765
(with pressure pot)NozzleE
BrushApplicable — for small-area repair onlyTypical thickness 40–50 µm (1.6–2.0 mils)
Roller applicationApplicable — for small-area repair onlyTypical thickness 40–50 µm (1.6–2.0 mils)
ThinnerInternational GTA220Do not exceed the thinning limits of local environmental regulations
CleanerInternational GTA822
Interruption of workDo not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International thinner.

Mixed paint should not be resealed. If work is interrupted for too long, mix a fresh batch of paint for application.

CleaningAll equipment should be cleaned immediately after use with International thinner. Flushing spray equipment periodically during daily work is good practice. Cleaning frequency depends on the volume sprayed, temperature, spraying time, including delays, and other factors.

All surplus paint and empty containers must be disposed of in accordance with the appropriate local laws/regulations.

Product Characteristics

To ensure good anticorrosive performance, it is essential that the minimum dry film thickness of the coating system reaches 40 µm (1.5 mils). To obtain a uniform film at this thickness, thinning with approximately 10% International thinner is required.

When Interzinc 72 is applied by brush or roller, multiple coats are necessary to achieve the specified total system dry film thickness.

The temperature of the surface to be coated must be at least 3 °C (5 °F) above the dew point.

This product does not cure adequately below 5 °C (41 °F). For optimum performance, curing should take place above 10 °C (50 °F).

When Interzinc 72 is used as the primer for coating systems subject to immersion, a minimum dry film thickness of 65 µm (2.5 mils) must be ensured to provide sufficient anticorrosive performance.

Over-application of Interzinc 72 will extend the minimum recoating time and handling time, adversely affecting long-term recoating performance.

Avoid excessive film thickness, otherwise cracking may occur when recoated with a high-build coating.

If Interzinc 72 is exposed to outdoor environments before topcoating, ensure all zinc salts are removed prior to coating application and select a compatible recommended topcoat.

Interzinc 72 is not suitable for exposure to acidic or alkaline environments.

This product holds the following specification approvals: • BS5493 (1977): DF and KP1B • BS4652:1995 • British Gas Specification PA9 and PA10. Note: VOC value is typical and for guidance only. The value may vary depending on factors such as colour differences and normal manufacturing tolerances.

System compatibility

Interzinc 72 can be recoated with a wide range of high-performance coatings, including:

Intercure 200Intergard 411
Intercure 420Intergard 475HS
Intercure 422Interseal 670HS
Intergard 251Intersheen 73
Intergard 269Intertuf 708
Intergard 400Interzone 505
Intergard 405Interzone 954 Intergard 410 For other suitable primers/topcoats, consult International Paint.

Supplementary information

For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.comIn the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate. These sections are also available as separate publications on request.

Safety precautions

This product must be applied at the production site by professional applicators in accordance with the recommendations in this manual, the Material Safety Data Sheet and the instructions on the container label. Do not use this product without first reviewing the Material Safety Data Sheet (MSDS) that International Paint provides for its customers.

All work related to the application and use of this product must be carried out in accordance with the relevant national health, safety and environmental standards and regulations.

If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation.

If in doubt about the suitability of this product for the intended use, consult AkzoNobel for further advice.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
10 L8 L10 L2 L2.5 L

For other packaging sizes, contact AkzoNobel.

Shipping weight

Packaging SpecificationsComponent AComponent B
10 L27.3 kg2.1 kg

Storage

Shelf lifeAt 25 °C (77 °F), Component A: 12 months, Component B: 18 months, after which inspection is required. Store in a dry, cool place away from heat sources and ignition sources.

Issue date

© 2026/5/27 AkzoNobel. All rights reserved.

All registered trademarks mentioned in this publication are licensed to or owned by AkzoNobel.

www.international-pc.com

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, zinc-rich primer, epoxy coating

View all AKZONOBEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery